Leviton Decora Smart Z-Wave dimmers are compatible with different types of loads. Choosing the correct load type will increase compatibility and provide proper operation.
Incandescent Loads (Default):
- Enter Programming Mode by holding the top of the paddle for 7 seconds (the Locator LED will turn amber), and then release (the Locator LED will begin to blink amber).
- Tap the top of the paddle 4 times. The Locator LED will quickly flash green and amber.
- Tap the top of the paddle 4 times.
- The Locator LED will flash green and amber 3 times to confirm the selection.
LED Loads:
- Enter Programming Mode by holding the top of the paddle for 7 seconds (the Locator LED will turn amber), and then release (the Locator LED will begin to blink amber).
- Tap the top of the paddle 4 times. The Locator LED will quickly flash green and amber.
- Tap the top of the paddle 5 times.
- The Locator LED will flash green and red 3 times to confirm the selection.
CFL Loads:
- Enter Programming Mode by holding the top of the paddle for 7 seconds (the Locator LED will turn amber), and then release (the Locator LED will begin to blink amber).
- Tap the top of the paddle 4 times. The Locator LED will quickly flash green and amber.
- Tap the top of the paddle 6 times.
- The Locator LED will flash red/amber 3 times to confirm the selection.